NEMA Plug Chart for Commercial Kitchen Equipment, Plus 208V vs 240V
NEMA plug chart for kitchen equipment with volts, amps, phase and real models, plus 208V vs 240V, what makers say and what to check on a used unit.
A NEMA plug code gives the plug's configuration and amp rating: on Hubbell's chart, a 5-15P is a 125-volt, 15-amp plug, a 6-30P is a 250-volt, 30-amp plug, and a 15-50P is a three-phase, 250-volt, 50-amp plug. A plug that fits doesn't prove the voltage matches: Sterling's SP208-6-1-AF (208V) and SP240-6-1-AF (240V) both ship with an L6-30P. This guide is general information, not electrical advice. A licensed electrician and your local code decide what is safe in your building.
NEMA plug chart for kitchen equipment
Ratings come from Hubbell's straight blade and Twist-Lock charts. Examples come from manufacturer documents we opened. "None found" doesn't mean no such equipment exists.
| Plug | Device rating | Amps | Phase | Poles / wires | Example from a manufacturer document |
|---|---|---|---|---|---|
| 5-15P | 125V | 15 | Single | 2 / 3, grounding | True T-49-HC (115/60/1, 5.4 A); Hoshizaki AM-50BAK (115V/60/1); Fetco E2231US-1A115-PA011 (120V, 13.0 A) |
| 5-20P | 125V | 20 | Single | 2 / 3, grounding | Fetco E2231US-1A123-PA012 (120V, 19.7 A) |
| 6-15P | 250V | 15 | Single | 2 / 3, grounding | Alto-Shaam 1000-UP, 208-240V version |
| 6-20P | 250V | 20 | Single | 2 / 3, grounding | TurboChef Sota i1-9500-104 (208/240V, 20 A) |
| 6-30P | 250V | 30 | Single | 2 / 3, grounding | TurboChef Bullet ENC-9600-601 (208/240V, 30 A); TurboChef Sota i1-9500-1 |
| 6-50P | 250V | 50 | Single | 2 / 3, grounding | Vollrath JPO14 PO4-20814L-R (208V, 27 A); Sterling SP208-10-1-AF (208/60/1, 48.08 A) |
| 14-30P | 125/250V | 30 | Single | 3 / 4, grounding | None found |
| 14-50P | 125/250V | 50 | Single | 3 / 4, grounding | None found |
| 15-20P | 250V | 20 | Three | 3 / 4, grounding | None found |
| 15-30P | 250V | 30 | Three | 3 / 4, grounding | None found |
| 15-50P | 250V | 50 | Three | 3 / 4, grounding | Sterling SP208-14-3-AF (208/60/3, 39.97 A) |
| 15-60P | 250V | 60 | Three | 3 / 4, grounding | Pitco SELV184, optional cordset, 208V or 240V three-phase |
| L6-30P | 250V | 30 | Single | 2 / 3, grounding | Alto-Shaam CTX4-10E, 208V single-phase (22.5 A); Sterling SP208-6-1-AF |
| L14-30P | 125/250V | 30 | Single | 3 / 4, grounding | Alto-Shaam EC2SYS-96, 120/208-240V version |
| L15-30P | 250V | 30 | Three | 3 / 4, grounding | Sterling SP208-10-3-AF (208/60/3, 27.76 A) |
Of the rows above, Hubbell marks only the 15 and L15 series as three-phase, so "Single" elsewhere is our reading of the chart. Hubbell counts the ground as a wire. "P" means plug, "R" means the matching receptacle, and "L" marks a locking device.
Need a NEMA plug chart PDF? Hubbell's one-page straight blade chart shows the blade shapes.
What is the difference between 208V and 240V?
They usually come from different building services, and the same machine can make noticeably less heat on 208V.
| Service | Between hot legs | Hot to neutral | Three-phase? |
|---|---|---|---|
| 120/208V wye | 208V | 120V | Yes |
| 120/240V single-phase | 240V | 120V | No |
| 240V high-leg delta | 240V | 120V on two phases; the high leg measures 208V | Yes |
In a data center power paper, Schneider Electric describes 208/120V as the traditional North American three-phase branch distribution, with 120 equal to 208 divided by the square root of 3. It also explains the single-phase case: 240V across the transformer's outer terminals and 120V from either one to the neutral. The high-leg row shows why a stray "208" reading doesn't settle anything: Schneider says that leg's 208V to neutral isn't a usable downstream voltage.
All three services can supply 120V, so a 120V unit such as the True T-49-HC doesn't raise this question. It comes up with 6, 14, 15, L6, L14 and L15 plugs and with hardwired units.
How do you find out which voltage your building has?
Ask a licensed electrician to confirm it at the panel and at the outlet you plan to use. Wolf, a residential appliance maker, says homes typically have 240V and commercial and high-rise buildings typically have 208V, but that this varies greatly with local codes, electrical requirements and building age, and it sends customers to a certified electrician.
Don't test it yourself. OSHA's workplace rule says only qualified persons may perform testing work on electric circuits or equipment. Ask for four things in writing: volts between hot legs, single or three phase, the circuit's amp rating, and the receptacle type.
Can you run 208V equipment on 240V, or 240V equipment on 208V?
It depends on the model. In the documents we opened, most equipment falls into three groups.
Built for one voltage. Treat these as a no unless the maker says otherwise in writing. We found no maker approving a single-voltage unit on the other voltage.
| Model | What the maker says |
|---|---|
| Cooking Performance Group 351FEC100DDC (208V), 351FEC100DDD (240V) | You cannot convert voltages. With the wrong voltage, you need a unit with the correct voltage |
| Vulcan HEG36E griddle | Specify voltage when ordering. If supply and equipment voltages don't agree, do not proceed with installation |
| Southbend EH-10SC | Input voltage and phase must match the serial plate |
| Sterling SP208-14-3-AF, SP240-14-3-AF | Sold as separate 208V and 240V models with the same 15-50P |
Dual-rated, with lower output on 208V. These sheets list both voltages, but the numbers differ. The last column is our arithmetic.
| Model | Connection | At 208V | At 240V | 208V as share of 240V |
|---|---|---|---|---|
| Fetco E2232US-1B230-PA010 | Terminal block | 4.5 kW | 6.0 kW | 75% |
| Alto-Shaam CTX4-10E, three-phase | No cord, no plug | 5.4 kW, 15.0 A | 7.48 kW, 18.0 A | 72% |
| Alto-Shaam EC2SYS-96 | L14-30P | 3.9 kW, 18.8 A | 5.2 kW, 21.7 A | 75% |
| BUNN CWTF-DV-TC | Not stated on sheet | 2,750 W, 11 A | 3,170 W, 13 A | 87% |
| TurboChef Bullet ENC-9600-601 | 6-30P | 5.99 kW | 6.675 kW | 90% |
The 75% figures fit resistance-heater math: 208 divided by 240, squared, is about 0.75. That's our inference, not a maker's statement, and it won't hold for machines with other loads, such as the Bullet's 3.5 kW microwave input listed at both voltages. When choosing among its models, Sterling says higher kW means faster cook times, and Wolf says lower voltage can lengthen preheat and recovery on its residential ovens. TurboChef says its Smart Voltage Sensor doesn't compensate for lack of or over voltage, and that correct supply is the owner's responsibility.
Dual-rated, but set up in the field. Lang says its 208/240V ECOD and ECOF ovens ship as 208V and must be field converted for a 240V supply, by personnel qualified to work with electricity. On a used unit, ask how it was last set.
Some units instead list a wide range: Hoshizaki's KM-1301SAH, a 208-230V ice machine since replaced by the KM-1301SAJ, lists an operating range of 187 to 253V.
One label confuses buyers: "120/208V" isn't a 120V machine. BUNN says the higher number on such a rating is the supply voltage needed, and the 120V only feeds some components.
Does single phase or three phase matter?
Yes. Phase changes the amps and often the plug. Pitco's SELV184 (17 kW) lists 82 A single-phase and 48 A three-phase at 208V. Cooking Performance Group's 351FEC100DDC (11 kW) lists 53 A and 32 A.
Some units can change phase. Cooking Performance Group, Southbend and Lang describe field phase conversion, and TurboChef lists the Sota as field-configurable with a service call, though the sheet's U.S. and Canada models are all single phase. Others are listed only one way, like Sterling's SP208-14-3-AF at 208/60/3. A 15 or L15 series plug means a three-phase supply, so settle that with your electrician before you buy.
What does hardwired mean on a used unit?
There's no plug to match. The Alto-Shaam CTX4-10E's 208-240V three-phase version is listed "No cord, no plug," Fetco's E2232US-1B230-PA010 uses a terminal block, and Hoshizaki says the KM-1301SAH must be hard-wired at the installation site. Hoshizaki's KM-515MAJ sheet lists circuit wires and a 20 A maximum fuse or HACR breaker but no plug. Vulcan says its griddle isn't fused, so it needs a fused circuit with a disconnect as required by local authorities.
Our inference: budget for an electrician at both ends, to disconnect it at pickup and connect it at your site.
What are the safety rules for plugs, adapters and breakers?
- Don't swap a plug to make it fit. OSHA requires listed equipment to be installed and used according to its listing or labeling instructions, and says plugs and receptacles may not be altered in a way that breaks grounding continuity.
- Don't use an adapter to bridge a mismatch. OSHA's text bars adapters that interrupt the grounding connection. Our advice goes further, because an adapter that keeps the ground still doesn't fix a voltage or amp mismatch. OSHA also requires that receptacles on different voltages at one premises not take interchangeable plugs.
- Leave breakers and wiring to a licensed electrician. Details vary by model: TurboChef requires a type D breaker on the Sota, Hoshizaki's AM-50BAK sheet says that where GFCI is required it must be a GFCI breaker and not a GFCI receptacle, Alto-Shaam requires a dedicated circuit for the CTX4-10E, and True calls for a dedicated 15-amp outlet for the T-49-HC.
- Local code governs. Lang and Vulcan both point to local codes and NFPA 70, the National Electrical Code. We didn't open the NEC text, so this guide doesn't summarize it.
What should you check on a used unit before pickup?
Food Service Surplus connects buyers and sellers. It doesn't inspect, test, ship or guarantee equipment, so get these from the seller. Buying used restaurant equipment covers the wider inspection.
- Nameplate photo. Model, serial, volts, amps or kW, phase and Hz, all legible. If the plate is behind a panel, have a technician take the photo with the power disconnected.
- Hz. True lists a 230-240/50/1 version of the T-49-HC, and Alto-Shaam lists 50 Hz options for the CTX4-10E. Our inference: a surplus unit could be an export build, so check.
- Plug or hardwire. A photo of the plug face, or of the connection point only if it's visible without opening a cover. Anything behind a cover waits for an electrician with the power off.
- Full model string. A short name can hide the voltage, as with Sterling's SP208 and SP240.
- Last setup. Which voltage and phase it ran on, and whether anyone converted it.
- Your electrician's sign-off. Send the nameplate photo before you pay or schedule pickup.
Browse used commercial cooking equipment, used commercial refrigeration or all restaurant equipment. For planning, see the commercial kitchen equipment checklist, commercial refrigerator sizes, the coffee shop equipment list and Type 1 vs Type 2 hoods.
Seller checklist for listing electrical equipment
- A clear nameplate photo, plus the full model string. Don't open a panel to get it unless the unit is disconnected and a qualified person is doing it.
- Volts, amps or kW, phase and Hz exactly as printed.
- Plug type with a photo of the blades, or "hardwired."
- The voltage and phase it last ran on, and any conversion you know of.
- Whether it's running now, and whether a buyer can see it powered on.
- Who disconnects it, and whether an electrician is needed before pickup.
List it through sell used restaurant equipment.
Frequently asked questions
Can I plug a 240V appliance into a 208V outlet? Only if the nameplate or the maker's document covers 208V. A plug that fits isn't proof, because some makers use the same plug on 208V and 240V models.
What is the difference between a 6-30P and an L6-30P? Hubbell rates both at 250V with 2 poles and 3 wires, and lists L6-30 on its Twist-Lock chart as a locking device. They are separate configurations, so ask an electrician about the receptacle instead of using an adapter.
Does dual-rated equipment lose power on 208V? In the sheets that list separate figures, yes. Fetco's E2232US-1B230-PA010 goes from 6.0 kW at 240V to 4.5 kW at 208V, and the Alto-Shaam CTX4-10E goes from 7.48 kW to 5.4 kW on three-phase. Some sheets, like TurboChef's for the Sota i1-9500-1, give one figure for 208/240V, so don't assume either way.
Can I change the plug on used equipment? Don't do it yourself to make a unit fit. A new plug doesn't change the voltage, amps or phase the unit needs, so have an electrician review the nameplate and the maker's instructions first.
How do I know if my building is 208V or 240V? Ask a licensed electrician. Wolf notes that the typical pattern varies with local codes and building age, and OSHA limits testing work to qualified persons.
Sources
Specifications change, so go by the nameplate and the document for your exact model. Dates are the revision shown on each document. Some manufacturer documents here are hosted by dealers or manual sites.
- Hubbell: NEMA Straight Blade Devices chart (2017) and Twist-Lock Devices chart (2017)
- True: T-49-HC spec sheet
- Hoshizaki: AM-50BAK (3/11/26), KM-515M_J (2/23/18) and KM-1301SAH product page
- Fetco: CBS-2230 NG brewers
- BUNN: CWTF-DV-TC (7/21/26)
- TurboChef: Bullet product page, Encore/Bullet submittal package, DOC-1349 Rev G (10/17) and Sota spec sheet, DOC-1204 Rev K (8/16)
- Alto-Shaam: CTX4-10E, CTX-SPC-0003 (6/25), EC2SYS-96 series, #78B (8/15) and 500-S to 1000-UP manual, electrical page
- Sterling: Steam PRO ordering information
- Vollrath: 68-inch conveyor pizza ovens, JPO14 and JPO18
- Pitco: SELV184(X), L10-576 Rev 0 (12/14)
- Cooking Performance Group: 351FEC100DD and 351FEC200DD manual (12/2024)
- Vulcan: Heavy duty electric griddle manual (2/21)
- Southbend: Marathoner Gold half-size electric convection ovens, manual 1184093
- Lang: ECOF and ECOD-AP manual
- Schneider Electric: High-Efficiency AC Power Distribution for Data Centers, FAQ FA174504 and FAQ FA123686
- Wolf: Determining 208 volt or 240 volt service and oven performance on 208 volt supply
- OSHA: 29 CFR 1910.303, 1910.304 and 1910.334
Related guides
- Bar Equipment List: Underbar, Refrigeration and Glassware Checklist
A bar equipment list with maker specs for ice bins, bar sinks, glass washers, back bar coolers and draft, plus FDA Food Code items and used-buying checks.
- Coffee Shop Equipment List: What You Need, New or Used
A coffee shop equipment list with maker specs for espresso machines, grinders and brewers, utilities to plan first and what to check on used pieces.
- Commercial Refrigerator Sizes: Reach-In, Undercounter, Prep and Back Bar
Commercial refrigerator sizes from manufacturer spec sheets: reach-in, undercounter, chef base, prep and back bar dimensions, plus clearances and plugs.